Epoxy, Polymeric Gel & PU Grouting

 

The leakage can be treated from the negative side by means of pressure grouting without the need to hack and repair the original waterproofing membrane.
The procedure is relatively fast, straight forward and results in lesser inconvenience to the occupants.

 

STEP 1 – Checking the leakage path & cleaning the surface.

STEP 2 – Drilling of injection ports.

STEP 3 – Installing injection packers around the leak spot.

STEP 4 – Checking and ensuring that the packers are secured.

STEP 5 – Pumping of water at low pressure followed by the pumping of the chemical into the crack line/leak path using a pressure pump.

STEP 6 – Patching up of the holes.